BioDur® Carpenter CCM® Alloy Cobalt

. BioDur® Carpenter CCM® alloy is a non-magnetic cobalt-chromium-molybdenum alloy exhibiting high strength, corrosion resistance, and wear resistance. The alloy is a high

contact

Biodur® CCM / BioBlu / ACUBE 100 - Specialty Alloys

1  · Biodur® CCM is a non-magnetic cobalt-chromium-molybdenum alloy exhibiting high strength with corrosion and wear resistance. The alloy is a high nitrogen, low carbon

contact

BIO-DUR CARPENTER CCM ALLOY | Alloy Digest | ASM

199531 · Abstract. BIO-DUR CARPENTER CCM ALLOY is a high nitrogen, low carbon wrought version of ASTM F75 cast alloy and used in the orthopedic implant

contact

Biodur® 108 - Specialty Alloys | Carpenter Technology

1  · The resistance of Biodur® 108 to pitting and crevice corrosion is superior to 316L alloy and equivalent to the 22Cr-13Ni-5Mn alloy and 734 alloys. It is produced by the

contact

Micro-Melt® Biodur® CCM Plus® - Specialty Alloys

1  · Micro-Melt® Biodur® CCM Plus® is a non-magnetic, cobalt-chromium-molybdenum alloy exhibiting high strength, corrosion resistance, and wear resistance. This alloy is a

contact

Carpenter BioDur™ CCM® Medical Implant Alloy,

11  · Data provided by Carpenter Technology Corporation.Medical Implant Alloy. Non-magnetic Co-Cr-Mo alloy exhibiting high strength, corrosion resistance, and wear

contact

Micro-Melt® Biodur® CCM Low Nickel - Specialty Alloys

2023324 · Micro-Melt® Biodur CCM Low Nickel is a non-magnetic, cobalt-chromium-molybdenum wrought alloy exhibiting high strength, corrosion resistance, and wear

contact
[PDF]

CarTech BioDur® CCM® Alloy - Carpenter Technology

2021211 · CarTech® BioDur® CCM® Alloy Page:3of9 € Poisson'sRatio€ 0.300 ModulusofElasticity(E)€ 35.0 x103 ksi ModulusofRigidity(G)€ 13.4 x103 ksi Typical

contact

Biodur® 316LS - Specialty Alloys | Carpenter Technology

2  · Biodur® 316LS stainless steel is an electro-slag remelted (ESR) or vacuum arc remelted (VAR), low carbon, high nickel and molybdenum version of 316 stainless. The

contact

BIO-DUR CARPENTER CCM ALLOY | Alloy Digest | ASM

199531 · Abstract. BIO-DUR CARPENTER CCM ALLOY is a high nitrogen, low carbon wrought version of ASTM F75 cast alloy and used in the orthopedic implant industry. This datasheet provides information on composition, physical properties, hardness, and tensile properties. It also includes information on forming, heat treating, and machining.

contact
[PDF]

Knee Prosthesis Biomaterial Selection by Using MCDM

20211222 · Micro‐Melt® BioDur® Carpenter CCM® alloy Annealed at 1093 ⁰C/30 minutes M8 Carpenter MP35N Alloy 35 % deformed and aged at 538 ⁰C/4 h M9 Carpenter L‐605 Alloy Annealed at 1204⁰C M10 CP Titanium Grade 4 Annealed M11 Titanium Alloy Ti 6Al‐4V ELI Recrystallized

contact

CarTech® Micro-Melt® BioDur® CCM® Alloy Carpenter

2023320 · This alloy is a powder metallurgy version of CarTech BioDur CCM alloy (ASTM F 1537 Alloy 1), which is a high nitrogen, low carbon wrought version of ASTM F 75 cast alloy. CarTech Micro-Melt BioDur Carpenter CCM alloy is produced by vacuum induction melting (VIM) followed by gas atomization and hot isostatic pressing to produce

contact

CarTech® BioDur® CCM Plus® Alloy Carpenter

202323 · This alloy is a high carbon version of CarTech BioDur CCM alloy and meets the requirements of ASTM F1537, ASTM F799, ISO 5832-12 and ISO 5832-4. CarTech BioDur CCM Plus alloy is a wrought powder metallurgy product produced by vacuum induction melting (VIM) followed by gas atomization and hot isostatic pressing to produce

contact

BIODUR CCM PLUS ALLOY | Alloy Digest | ASM Digital

199551 · Abstract. BIODUR CCM PLUS ALLOY is a high carbon version of BioDur Carpenter CCM Alloy (Alloy Digest Co-96, March 1995), produced by vacuum induction melting, followed by inert gas atomization and hot isostatic pressure. Applications are in the orthopedic industry. This datasheet provides information on composition, physical

contact
[PDF]

CarTech Micro-Melt®BioDur®CCM®Alloy

2021211 · CarTech® Micro-Melt®BioDur®CCM®Alloy Page:2of6 Properties PhysicalProperties SpecificGravity€ 8.29 Density€ 0.2995 lb/in³ MeanSpecificHeat 73°F 0.1061 Btu/lb/°F 210°F 0.1123 Btu/lb/°F 570°F 0.1252 Btu/lb/°F 1100°F 0.1410 Btu/lb/°F 1700°F 0.1570 Btu/lb/°F 1800°F 0.1580 Btu/lb/°F € 2012°F 0.1599 Btu/lb/°F MeanCTE

contact

BioDur® 108 Stainless Steel | Carpenter Additive

1  · BioDur® 108 is an FDA approved, essentially nickel- and cobalt-free alternative to other stainless steel options and is currently used for medical applications such as implantable orthopedic devices, high-strength surgical instrumentation, and orthodontic devices. Typically, devices and instruments are produced via subtractive manufacturing ...

contact
[PDF]

Cobalt CCM, Cobalt BC, Implantate - kleinmetals

20181030 · COBALT CCM ® Kobalt-Chrom-Molybdänlegierung, austenitisch, korrosionsbeständig ... Diese Kobalt-Chrom-Molybdän-Implantatlegierung ist die Carpenter-Güte MicroMelt® Biodur ... AISI/SAE/ASTM ASTM F1537 alloy 1 ISO 5832-12 Euronorm EN Sonstige UNS R31537 C Si Mn Cr Mo Ni Fe N Co max. max. max. 26.00 5.00 max. max.

contact

Biodur® CCM® Alloy 1, Implant Quality | 스틸맥스

20211019 · Biodur® CCM® Alloy 1, Implant Quality. 인성과 연성, 내피로성, 내마모성, 높은 기계적 성질을 가지는 재료입니다. 주요 원소 Co + Cr + Mo 합금량이 98.5% 수준에 이르는 초합금입니다. 티타늄 합금, 니켈 base 합금과 함께 인체에 사용하며, 고관절 등, 관절 재료로 쓰입니다 ...

contact

BioDur CCM Plus Stockist, BioDur CCM Plus Equivalent

2017628 · Technical specifications of American high temperature alloys BioDur CCM Plus datasheet, BioDur CCM Plus Chemical compositions, BioDur CCM Plus mechanical properties from Steelmaking, ESR melted, Blooming, Forging, Hot rolling, Heat treatment, Straightening, Ultrasonic test, Cold working or Machined. ... Carpenter 20 Mo 6; AISI 660

contact

BIO-DUR CARPENTER CCM ALLOY | Alloy Digest | ASM

199531 · Abstract. BIO-DUR CARPENTER CCM ALLOY is a high nitrogen, low carbon wrought version of ASTM F75 cast alloy and used in the orthopedic implant industry. This datasheet provides information on composition, physical properties, hardness, and tensile properties. It also includes information on forming, heat treating, and machining.

contact

CarTech® Micro-Melt® BioDur® CCM® Alloy Carpenter

202326 · This alloy is a powder metallurgy version of CarTech BioDur CCM alloy (ASTM F 1537 Alloy 1), which is a high nitrogen, low carbon wrought version of ASTM F 75 cast alloy. CarTech Micro-Melt BioDur Carpenter CCM alloy is produced by vacuum induction melting (VIM) followed by gas atomization and hot isostatic pressing to produce

contact

BIODUR CCM PLUS ALLOY | Alloy Digest | ASM Digital

199551 · Abstract. BIODUR CCM PLUS ALLOY is a high carbon version of BioDur Carpenter CCM Alloy (Alloy Digest Co-96, March 1995), produced by vacuum induction melting, followed by inert gas atomization and hot isostatic pressure. Applications are in the orthopedic industry. This datasheet provides information on composition, physical

contact

Materials for Medical Manufacturing

201151 · A few of the most commonly used materials for implants are titanium, Ti-6Al-4V, stainless steels [Carpenter’s BioDur 316LS alloy], and cobalt alloys [BioDur CCM and BioDur CCM Plus alloys],” Guitterrez notes, “and those used for instruments are typically made from other classes of stainless steel [Project 70+, Custom 630, Custom 455 ...

contact

Stainless Steel | Banner Medical Innovations, Inc.

BioDur® 316LS Stainless; BioDur® 108 Alloy; BioDur® Carpenter CCM® Alloy; BioDur® 22Cr-13Ni-5Mn-Stainless; Custom 455® Stainless; Custom 465® Stainless; Project 70® + Custom 630 (17Cr-4Ni) Stainless Sandvik Bioline 316LVM; Type 416 Stainless Cond. H (Rc 32 – 38) Type 420 Stainless; Type 440A Stainless; Type 440C Stainless; Type 17-4 PH

contact

New Alloy Emerges in Response to Patient Sensitivities

202093 · Eliminating cobalt content in situ as a replacement for BioDur CCM, the high-strength and fatigue properties are maintained, inferred by the close relationship between strength and fatigue in austenitic alloys. Only moderate levels of cold work are necessary to drive up the Yield Strength and Ultimate Tensile Strength of BioDur 108.

contact

Foreign alloys - Manufacturing and delivering metals.

20221130 · Главная / Store / Cobalt and its alloys / Foreign alloys. Search in current category. Price. from to. Stellite alloy. AlNiCo. Haynes. CoCr. F. MULTIMET . PHYNOX. SY 35N. ULTIMET . ULTIMET . Del-Braze 4783. Marker P 42H ... BioDur Carpenter CCM . BioDur CCM Plus - Carpenter. Carpenter L-605 - Carpenter. Carpenter MP35N .

contact

Forgings W73041 - Manufacturing and delivering metals.

1  · Главная / Store / Cobalt and its alloys / Foreign alloys / W73041 / Forgings W73041. Our enterprise manufactures and delivers W73041 forgings. Possible dimensions. Thickness 50 – 1,000 mm x width up to 2,000 mm x length up to 6,000 mm. Dimensions and weight are established at the customer’s request. All products being delivered meet ...

contact

Stainless Steel Implant Quality Co-Cr-Mo Alloy - Prices,

Biodur Carpenter CCM Alloy(tm) CCM Co-Cr-Mo Implant Quality Biodur CCM Alloy(tm) Specifications: No Specifications. Chemistry Data. MSO currently has no data available for this grade. General Information. Principal Design Features. Medical implant quality stainless steel.

contact

ASM Co-97

This alloy is a high carbon version of BioDur Carpenter CCM Alloy (Alloy Digest Co-96), produced by vacuum induction melting, followed by inert gas atomization and hot isostatic pressure. Applications are in the orthopedic industry. Product Details Published: 05/01/1995

contact
[PDF]

Knee Prosthesis Biomaterial Selection by Using MCDM

20211222 · Micro‐Melt® BioDur® Carpenter CCM® alloy Annealed at 1093 ⁰C/30 minutes M8 Carpenter MP35N Alloy 35 % deformed and aged at 538 ⁰C/4 h M9 Carpenter L‐605 Alloy Annealed at 1204⁰C M10 CP Titanium Grade 4 Annealed M11 Titanium Alloy Ti 6Al‐4V ELI Recrystallized

contact

Carpenter BioDur™ CCM Plus™ Medical Implant Alloy

Carpenter BioDur™ CCM Plus™ Medical Implant Alloy, Annealed 1093°C 2 hr. Data provided by Carpenter Technology Corporation. Annealing followed by water quench and low stress grinding prior to tensile testing. Medical Implant Alloy. Non-magnetic Co-Cr-Mo alloy exhibiting high strength, corrosion resistance, and wear resistance.

contact

Knee Prosthesis Biomaterial Selection by Using MCDM Solver

20211215 · M5 BioDur® Carpenter . CCM® Alloy Annealed . M6 BioDur® CCM Plus® Alloy . Annealed at . 1093 ⁰ C/1 h . M7 Micro ‐ Melt® BioDur® Carpenter CCM® alloy . Annealed at . 1093 .

contact

BioDur™ Technical Data Sheets

This page has links to all data sheets in MatWeb for the tradename BioDur™. We have several search tools, listed above, that give you more efficient methods to reach the information that you need. BioDur™ has 15 material (s) in the MatWeb database. Back to Tradename List. Carpenter BioDur™ 316LS Stainless Medical Implant Alloy, 35% Cold ...

contact

BioDur® CCM Plus® Alloy Cobalt

This alloy is a high carbon version of BioDur Carpenter CCM® alloy and meets the requirements of ASTM F1537, ASTM F799, ISO 5832-12 and ISO 5832-4. BioDur CCM Plus alloy is a wrought powder metallurgy product produced by vacuum induction melting (VIM) followed by gas atomization and hot isostatic pressing to produce 100% dense billets.

contact

Carpenter BioDur™ CCM Plus™ Medical Implant Alloy,

Carpenter BioDur™ CCM Plus™ Medical Implant Alloy, Annealed 1093°C 1 hr. Data provided by Carpenter Technology Corporation.Annealing followed by water quench and low stress grinding prior to tensile testing.Medical Implant Alloy. Non-magnetic Co-Cr-Mo alloy exhibiting high strength, corrosion resistance, and wear resistance.

contact

BioDur™ product list - Carpenter Technology Corporation

Carpenter BioDur™ CCM Plus™ Medical Implant Alloy, Annealed 1121°C 1 hr: Superalloy: Carpenter BioDur™ CCM Plus™ Medical Implant Alloy, Annealed 1149°C (2100°F) 1 hr: Superalloy: Carpenter BioDur™ CCM® Medical Implant Alloy, Annealed: Superalloy: Carpenter BioDur™ CCM® Medical Implant Alloy, Warm Worked: Superalloy

contact
[PDF]

Call 800.343 - Boston Centerless

201981 · medical alloys alloys tubing 455 custom 455® custom 465® biodur® 108 biodur® 316ls 316l (implant quality) ccm (cocrmo) trimrite® ti 6al-4v-eli 22-13-5 4130 (aq), (ht) 4140 (aq), (ht) 41l40 4150 4330 4340 (aq), (ht) 8620 (ht) 86l20 8740 (aq) 9310 (aq) 52100 etd-150 nitralloy 135 aluminum carbon copper hastelloy nickel kovar stainless tool ...

contact

BioDur CCM Plus Stockist, BioDur CCM Plus Equivalent

2017628 · Technical specifications of American high temperature alloys BioDur CCM Plus datasheet, BioDur CCM Plus Chemical compositions, BioDur CCM Plus mechanical properties from Steelmaking, ESR melted, Blooming, Forging, Hot rolling, Heat treatment, Straightening, Ultrasonic test, Cold working or Machined. ... Carpenter 20 Mo 6; AISI 660

contact

Biodur® 108 - Fort Wayne Metals

Biodur® 108. Biodur® 108 is an essentially nickel-free austenitic stainless steel with many of the same properties of other stainless steels, such as the high corrosion resistance of 316LVM, and strength similar to spring temper 304 stainless steel. ... Stainless alloys. 302;

contact